SafeGuard
← All assets

Data Campus Dallas 5

Data center · Dallas, United States · built 2000

Insured value
€7.73M
Occupancy
44%
Sensor coverage
40%
Maintenance
77d overdue
Equipment breakdown — why this score
updated 2h ago

Equipment breakdown risk building at Data Campus Dallas 5. Bearing/vibration pattern drifting from baseline; running hot vs. seasonal baseline. Estimated probability within 24h: 3%.

Probability 24h
3%
Probability 7d
9%
Probability 30d
24%
Risk velocity
+2.8 pts/h
Confidence
63%
Preventability
88%
Predicted score in 24h

Trailing 24h sensor trend, projected forward and re-scored — not the current snapshot repeated.

38↑Watch

Trigger for Equipment breakdown: Watch ≥25 · Elevated ≥50 · Critical ≥75 · change trigger

Contributing factors
Vibration signature25
bearing/vibration pattern drifting from baseline
Thermal drift23
running hot vs. seasonal baseline
Load anomaly12
motor drawing above rated load
Service interval overdue11
77 days since last service
Live sensor readings
temperature
28.26 °C
baseline 21°C
humidity
43.3 %
baseline 45%
water Flow
3.54 L/min
baseline 3L/min
water Pressure
4.84 bar
baseline 4.2bar
smoke
1.3 µg/m³
baseline 4µg/m³
electrical Load
67.17 %
baseline 60%
electrical Temp
41.15 °C
baseline 37°C
vibration
3.25 mm/s
baseline 2.1mm/s
door State
0 events
baseline 0.4events
motion
3.48 events
baseline 0.8events
seismic Activity
0.06 g
baseline 0.015g
co2
533.52 ppm
baseline 440ppm
decibel
56.79 dB
baseline 38dB
21.9°C · 11.5mm/24h · wind 11km/h
Derived signals
Estimated occupancy: ~3 people (interpreted from CO₂ at 533.52ppm)
Structural trend: drifting upward (+0.048 g/day sustained over 24h) — possible developing crack
Drone / aerial roof inspection

Upload a drone or aerial photo — SafeGuard analyzes it for damage and feeds the result into water-damage risk.

Analysis runs on real pixel data (staining, tone variance, edge discontinuities, corrosion hue) — not a placeholder score.

Claims & incident history
FloodPREVENTED

Storm surge caused ground-floor flooding at Data Campus Dallas 5. Caught by SafeGuard before loss occurred — figures below are the estimated avoided loss.

10 months ago · root cause: Coastal/storm exposure
€416k
Theft / intrusion

Inventory shrinkage traced to internal theft at Data Campus Dallas 5.

15 months ago · root cause: Insufficient CCTV coverage in stock areas
€49k
Flood

Storm surge caused ground-floor flooding at Data Campus Dallas 5.

26 months ago · root cause: Coastal/storm exposure
€516k
Theft / intrusion

Inventory shrinkage traced to internal theft at Data Campus Dallas 5.

30 months ago · root cause: Insufficient CCTV coverage in stock areas
€34k
Earthquake

Seismic activity caused structural damage at Data Campus Dallas 5.

33 months ago · root cause: Ground motion exceeding structural tolerance
€103k