Colocation Facility Leeds

Data center · Leeds, United Kingdom · built 2001

Insured value
€8.68M
Occupancy
70%
Sensor coverage
22%
Maintenance
118d overdue
Theft / intrusion — why this score
updated 2h ago

Theft / intrusion risk building at Colocation Facility Leeds. Door held open outside scheduled hours; motion detected outside occupancy hours. Estimated probability within 24h: 4%.

Probability 24h
4%
Probability 7d
11%
Probability 30d
29%
Risk velocity
+1.5 pts/h
Confidence
53%
Preventability
64%
Predicted score in 24h

Trailing 24h sensor trend, projected forward and re-scored — not the current snapshot repeated.

82↑Critical

Trigger for Theft / intrusion: Watch ≥25 · Elevated ≥50 · Critical ≥75 · change trigger

Contributing factors
Access-point anomaly24
door held open outside scheduled hours
After-hours motion19
motion detected outside occupancy hours
Occupancy signal (CO₂ + noise)10
no cross-validated occupancy signal
CCTV / sensor coverage gap10
only 22% of recommended coverage installed
Live sensor readings
temperature
22.15 °C
baseline 21°C
humidity
65.22 %
baseline 45%
water Flow
6.95 L/min
baseline 3L/min
water Pressure
4.38 bar
baseline 4.2bar
smoke
4.64 µg/m³
baseline 4µg/m³
electrical Load
64.42 %
baseline 60%
electrical Temp
34.01 °C
baseline 37°C
vibration
1.96 mm/s
baseline 2.1mm/s
door State
2.67 events
baseline 0.4events
motion
3.18 events
baseline 0.8events
seismic Activity
0.01 g
baseline 0.015g
co2
423.7 ppm
baseline 463ppm
decibel
59.06 dB
baseline 38dB
3.2°C · 0.5mm/24h · wind 28km/h
Derived signals
Estimated occupancy: ~0 people (interpreted from CO₂ at 423.7ppm)
Structural trend: stable, no sustained drift
Drone / aerial roof inspection

Upload a drone or aerial photo — SafeGuard analyzes it for damage and feeds the result into water-damage risk.

Analysis runs on real pixel data (staining, tone variance, edge discontinuities, corrosion hue) — not a placeholder score.

Claims & incident history
Flood

Storm surge caused ground-floor flooding at Colocation Facility Leeds.

3 months ago · root cause: Coastal/storm exposure
€497k
Water damagePREVENTED

Pipe burst overnight in a service riser at Colocation Facility Leeds after freezing temperatures. Caught by SafeGuard before loss occurred — figures below are the estimated avoided loss.

5 months ago · root cause: Uninsulated pipework, freeze event
€129k
Equipment breakdown

Critical motor failure halted operations at Colocation Facility Leeds.

28 months ago · root cause: Bearing wear beyond service interval
€181k
Equipment breakdown

HVAC compressor failure at Colocation Facility Leeds caused a partial shutdown.

29 months ago · root cause: Overdue service interval
€36k
Water damage

Water heater failure flooded a plant room at Colocation Facility Leeds.

34 months ago · root cause: End-of-life appliance
€5k