Colocation Facility Singapore 2

Data center · Singapore, Singapore · built 1995

Insured value
€13.7M
Occupancy
53%
Sensor coverage
69%
Maintenance
129d overdue
Fire — why this score
updated 2h ago

Fire risk building at Colocation Facility Singapore 2. Elevated particulate detected; +9% above baseline. Estimated probability within 24h: 4%.

Probability 24h
4%
Probability 7d
10%
Probability 30d
26%
Risk velocity
+3.5 pts/h
Confidence
79%
Preventability
82%
Predicted score in 24h

Trailing 24h sensor trend, projected forward and re-scored — not the current snapshot repeated.

51↑Elevated

Trigger for Fire: Watch ≥25 · Elevated ≥50 · Critical ≥75 · change trigger

Contributing factors
Smoke particulate36
elevated particulate detected
Electrical temperature19
+9% above baseline
Maintenance overdue11
129 days overdue
Power draw anomaly2
stable load
Live sensor readings
temperature
21.82 °C
baseline 21°C
humidity
51.99 %
baseline 45%
water Flow
3.31 L/min
baseline 3L/min
water Pressure
4.31 bar
baseline 4.2bar
smoke
10.02 µg/m³
baseline 4µg/m³
electrical Load
57.62 %
baseline 60%
electrical Temp
48.41 °C
baseline 37°C
vibration
3.59 mm/s
baseline 2.1mm/s
door State
2.66 events
baseline 0.4events
motion
0.35 events
baseline 0.8events
seismic Activity
0.05 g
baseline 0.015g
co2
619.61 ppm
baseline 448ppm
decibel
38 dB
baseline 38dB
12.3°C · 8.2mm/24h · wind 24km/h
Derived signals
Estimated occupancy: ~5 people (interpreted from CO₂ at 619.61ppm)
Structural trend: drifting upward (+0.042 g/day sustained over 24h) — possible developing crack
Drone / aerial roof inspection

Upload a drone or aerial photo — SafeGuard analyzes it for damage and feeds the result into water-damage risk.

Analysis runs on real pixel data (staining, tone variance, edge discontinuities, corrosion hue) — not a placeholder score.

Claims & incident history
Fire

Suspected arson incident at Colocation Facility Singapore 2 outside occupancy hours.

6 months ago · root cause: Unauthorized access, no ignition source identified
€158k
Flood

Nearby river overflow inundated the site at Colocation Facility Singapore 2.

7 months ago · root cause: Floodplain location
€857k
Equipment breakdown

Critical motor failure halted operations at Colocation Facility Singapore 2.

13 months ago · root cause: Bearing wear beyond service interval
€143k
Flood

Nearby river overflow inundated the site at Colocation Facility Singapore 2.

19 months ago · root cause: Floodplain location
€682k
Equipment breakdown

Critical motor failure halted operations at Colocation Facility Singapore 2.

25 months ago · root cause: Bearing wear beyond service interval
€80k
Equipment breakdown

HVAC compressor failure at Colocation Facility Singapore 2 caused a partial shutdown.

29 months ago · root cause: Overdue service interval
€44k